    概述

    • Entry-level CPU in the S7-1500F Controller product range
    • Can be used for safety functions up to SIL 3 according to IEC 61508 and up to PLe according to ISO 13849
    • Suitable for standard and fail-safe applications with medium requirements for program scope and processing speed
    • Used as central controller in production lines with central and distributed I/O
    • Supports PROFIsafe in centralized and distributed configuration
    • PROFINET IO IRT interface with 2-port switch
    • PROFINET IO Controller for operating distributed I/O on PROFINET
    • PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under a SIMATIC or non-Siemens PROFINET I/O controller
    • Isochronous mode

    Note:
    SIMATIC memory card required for operation of the CPU

    應用

    The CPU 1511-1 PN is the cost-effective entry-level CPU for standard and fail-safe applications with medium requirements for processing speed and speed of response in discrete production technology. With its RAM size, this CPU is also suitable for medium-sized applications. It can be used as a PROFINET IO controller or as distributed intelligence (PROFINET I-Device). The integrated PROFINET IO IRT interface is designed as 2-port switch so that a linear topology can be set up in the system. In addition, the CPU offers comprehensive control functionalities via easy-to-configure blocks as well as the ability to connect drives via standardized PLC-open blocks.

    設計

    The CPU 1511F-1 PN has:

    • a powerful processor:
      The CPU achieves a command execution time as low as 60 ns per binary command.
    • extensive RAM:
      230 KB for program, 1 MB for data
    • SIMATIC memory cards as load memory;
      permit additional functions such as datalog and archives
    • Flexible expansion possibilities: single-tier configuration with max. 32 modules (CPU + 31 modules)
    • Display with functions for the
      • Display of overview information such as station name, higher level designation, location designation, etc.
      • Display of diagnostic information
      • Display of module information
      • Display of display settings
      • Setting of IP addresses
      • Setting of date and time
      • Selection of the operating mode
      • Resetting of the CPU to factory settings
      • Disabling/enabling of the display,
      • Enabling of protection levels
      • display of safety mode, overall signature and date of the last download with signature change.
    • PROFINET IO IRT interface for connecting distributed I/O via PROFINET
    • Supports PROFIsafe in centralized and distributed configuration